Ion Chromatography System FM-ICS-A101 Catalog

Overview

Ion Chromatography System FM-ICS-A101 delivers precise ionic separation through a dual-channel system for simultaneous cation and anion detection. It features 42 MPa pressure capacity for accurate, high-throughput analysis. Integrated with an eluent generator for simplified operation. Built with a thermal control system to maintain column stability and consistent results. Our Ion Chromatography System ensures reliable ion detection across environmental, food, pharmaceutical, and chemical labs.

Specifications:

Eluent Types KOH, NaOH, LiOH, MSA
Eluent Concentration Range 0.1 to 100 mM
Eluent Generator Concentration Increment 0.1 mM
Eluent Generator Flow Rate Range 0.1 to 5.0 mL / min
Eluent Generator Maximum Pressure 35 MPa
Eluent Generator Minimum Pressure 5 MPa
Eluent Generator Accuracy of Gradient 0.0015
Vacuum Degree −70 kPa
Vacuum Degasser Internal Volume 300 μL
Vacuum Degasser Flow Rate Maximum 10 mL / min
Degassing Efficiency 90 % at 1.0 mL / min
Degassing Volume 7.5 mL
Flow Path Material Chemically Inert, Metal-Free PEEK, Compatible with Aqueous Eluents (pH 0–14) and Reversed-Phase Solvents
Pump Type Two-Stage Tandem System (piston + peristaltic pump)
Maximum Pressure of Pump 42 MPa
Pump Pressure Ripple ≤ 0.5 %
Flow Rate Range of Pump 0.001 to 12.000 mL / min
Pump Flow Precision ≤ 0.07 %
Pump Flow Accuracy ≤ 0.07 %
External Diameter of Tube 1 / 16 inch
Column Heater Operating Temperature Range Ambient + 5 to 60 °C
Column Heater Temperature Accuracy ± 0.1 °C
Column Heater Temperature Stability ≤ 0.1 °C/h
Columns Supported 2 mm, 3 mm, 4 mm, 5 mm ID (up to 250 mm length, 50 mm guard column)
Conductivity Detector Type Auto-range conductivity detector
Conductivity Detector Cell Volume ≤ 0.4 μL
Detection Range 0 to 50,000 μS / cm
Conductivity Detector Resolution ≤ 0.0020 nS / cm
Conductivity Baseline Noise ≤ 0.0002 μS / cm
Detector Baseline Drift ≤ 0.001 μS / 30 min
Conductivity Detector Maximum Pressure 10 MPa
Minimum Detectable Concentration (Cl⁻) ≤ 0.00008 μg / mL
Minimum Detectable Concentration (Li⁺) ≤ 0.00005 μg / mL
Suppressor Type Continuous Self-Regeneration Micro-Membrane Suppressor
Suppressor Maximum Pressure 6 MPa
Suppressor Void Volume < 40 μL (Anion), < 15 μL (Cation)
Temperature Control Accuracy ± 0.01 °C
Temperature Compensation 1.7 % / °C
Instrument Linearity (Conductivity) ≥ 0.999
Quantitative Repeatability (Conductivity) ≤ 0.06 %
Qualitative Repeatability (Conductivity) ≤ 0.05 %
Power 320 W
Dimensions 580 × 487 × 635 mm
Net Weight 52 kg
Gross Weight 60 kg

Features:

  • Automated Eluent-Generation
  • High-Sensitivity Detection
  • Self-Regenerating Suppressor
  • User-Friendly Interface
  • Advanced Safety-Alarms

Applications:

Ion Chromatography System FM-ICS-A101 is used for accurate, high-sensitivity detection and quantification of anions and cations in water, food, and chemical samples to ensure precise ionic composition analysis.

Accessories:

Accessory

Quantity

Ion chromatograph host

High-pressure double plunger advection pump

2

Conductivity detector

1

Auto valve unit

2

Anion column

1

Anion guard column

1

Cation column

1

Cation guard column

1

Anion suppressor

1

Cation suppressor

1

Chromatography software

1

Column heater

1

Spare parts kits

1

Built-in Eluent Generator SHRF-10 (anion)

1

Built-in Eluent Generator SHRF-10 (cation)

1

Peristaltic pump

2

Constant pressure degassing device

2

Gas-liquid separator

2

Online water purification module

1

Touch screen

1

Suction injection system

2

Mobile phone app

1

0.22 µm syringe filter

100