Coulometric Karl Fischer Titrator FM-AKT-A100

  • Method: Karl Fischer Coulometric Titration
  • Measuring cell: Two electrolysis measuring chambers
  • Amount of electrolyzed water: 10 ug to 1000 ug
  • Measurement range: 0 to 100 mg
  • Moisture range: 1 ppm to 100%
  • Precision of electrolyzed water: >1000 ug,0.2%
  • Display resolution: 0.1 ug
  • Display: 240×128 graphics dot-matrix LCD screen display
  • End point detection: Alternate current polarization method with a twin platinum electrode
  • End point indication: Visual display/print out
$7,713.00

Volumetric Karl Fischer Titrator FM-AKT-B100

  • Titration method: Volumetric Karl-Fischer reagent titration process
  • Measuring range: 0.1 mg H 2 O to 500 mg H 2 O (3 ppm - 100%)
  • Moisture resolution: 3 ppm
  • Number of burettes: 1 burette
  • Burette capacity: >25 ml
  • Burette resolution: 0.01 ml
  • Burette Repeatability: ≤ 0.01
  • Linear correlation coefficient: ≥ 0.998
  • End point detection: AC polarization potential difference detection
  • Minimum volume of addition: 0.005 ml
$4,575.00
Volumetric Karl Fischer Titrator FM-AKT-B101
  • Titration method: Volumetric Karl-Fischer reagent titration process
  • Measuring range: 0.1 mg H 2 O to 500 mg H 2 O (10 ppm - 100%)
  • Moisture resolution: 1 ppm
  • Number of burettes: 1 burette
  • Burette capacity: >15 ml
  • Burette resolution: 0.001 ml
  • Burette Repeatability: ≤ 0.005
  • Linear correlation coefficient: ≥ 0.999
  • End point detection: AC polarization potential difference detection
  • Minimum volume of addition: 0.005 ml
$9,825.00
Coulometric Karl Fischer Titrator FM-AKT-A200
  • Method: Karl - Fischer coulometric titration
  • Electrolytic current: 0 to 400 mA
  • Measuring range: 1μg to100 µg
  • Accuracy: 3 μg to 500 μg: ± 2 μg;
    >500 μg: 0.2%
  • Sensitivity: 0.1 µg
  • Calculation: Content calculations,
    Statistical calculations,
    Variety selection formula
  • Test method: Current and accurate real-time test
  • Printer: Line thermal printer
  • Printing: Automatic
  • Storage: ≤200 records with number and time stamp
$4,925.00

Karl Fischer titrator FM-AKT-C100

  • Testing range: 0.01 µg to 200 mg of H 2 O
  • Water content range: 0.0001 % to 100 %
  • Sensitivity: 0.01 µg H 2 O
  • Rate of electrolysis: 2.4 mg H2 O/min
  • Electrolysis current: Auto-control within 430 mA
  • Accuracy: Water content: 2 µg H2O to 100 µg H2O, Deviations: ≤ ±1 µg
    Water Content: 100 µg H2O to 1000 µg H2O, Deviations: ≤ ±2.9 µg
    Water Content: > 1000 µg H2O, Deviations: ≤ ±0.2% (excluding deviations of sample injection)
  • Ambient temperature: 5 °C to 40 °C
  • Relative humidity: < 85 %
  • Power consumption: < 40 W
  • Power supply: AC 220 V ± 10 %, 50 Hz ± 2.5 Hz
$4,750.00

Coulometric Karl Fischer Titrator FM-AKT-A101

  • Method: Coulometric titration (Coulomb analysis)
  • Measurement Range: 1 μg to 200mg
  • Electrolytic Current Control Range: 0 to 400mA automatic control
  • Accuracy: ±3 μg (10 μg to 1000 μg)
    ≤0.3% (1 Mg or More)
  • Sensitive Valve: 0.1μg H2O
  • Temperature Range: 5 to 40°C
  • Ambient Temperature: 15 to 25°C
  • Humidity: ≤ 85%
  • Display: Color LCD touchscreen
  • Power Consumption: < 40W
$6,500.00