Potentiostat FM-PT-A100 Catalog

Overview

Potentiostat FM-PT-A100 ±10V potential control capability ensures high-precision electrochemical regulation. Dual 24-bit converters deliver exceptional signal clarity and operational stability. High-resolution sensing captures ultra-low current with advanced accuracy. Fast response architecture enhances dynamic test performance across ranges. Robust design guarantees consistent measurement reliability for demanding research.

Specifications:

System Support 2-, 3-, or 4-electrode system
Potential Control Range ±10 V
Current Control Range ±2 A
Potential Control Accuracy 0.1%×full range ±1 mV
Current Control Accuracy 0.1%×full range
Potential Resolution 10 μV (>100 Hz), 3 μV (<10 Hz)
Current Sensitivity 1 pA
Rise Time <1 μs (<10 mA), <10 μs (<2 A)
Reference Electrode Input Impedance 10¹² Ω
Current Range 2 nA to 2 A, 10 ranges
Compliance Voltage ±21 V
Maximum Current Output 2 A
CV and LSV Scan Rate 0.001 mV to 10,000 V/s
CA and CC Pulse Width 0.0001 to 65,000 s
Current Increment During Scan 1 mA at 1 A/ms
Potential Increment During Scan 0.076 mV at 1 V/ms
SWV Frequency 0.001 to 100 kHz
DPV and NPV Pulse Width 0.0001 to 1000 s
AD Data Acquisition 16-bit at 1 MHz, 20-bit at 1 kHz
DA Resolution 16-bit, setup time: 1 μs
Minimum Potential Increment in CV 0.075 mV
IMP Frequency 10 μHz to 1 MHz
Low-Pass Filters Covering 8-decade
Operating System Windows 10/11
Interface USB 2.0
Signal Generator - Frequency Range 10 μHz to 1 MHz
Signal Generator - AC Amplitude 1 mV to 2500 mV
Signal Generator - DC Bias -10 to +10 V
Signal Generator - Output Impedance 50 Ω
Signal Generator - Waveform Sine wave, triangular wave, square wave
Signal Generator - Wave Distortion <1%
Scanning Mode Logarithmic/linear, increase/decrease
Signal Analyzer - Integral Time Minimum: 10ms or cycle time, Max: 10⁶ cycles or 10⁵ s
Signal Analyzer - Measurement Delay 0 to 10⁵ s
DC Offset Compensation - Potential Range -10 V to +10 V
DC Offset Compensation - Current Range -1 A to +1 A
Bandwidth 8-decade frequency range, auto/manual setting
Product Dimension (L×B×H) 360mm × 340mm × 140 mm
Packaging Dimension (L×B×H) 550mm × 400mm × 250 mm
Net Weight 6.5 kg
Packaging Weight 9 kg

Features:

  • Automatic range switching
  • High-bandwidth EIS
  • Ultra-fine voltage steps
  • Multi-mode waveform output
  • Software-driven sequencing

Applications:

Potentiostat FM-PT-A100 is ideal for corrosion science, electrocatalysis studies, battery research, materials analysis, electrochemical sensors, electrodeposition evaluation, energy-storage development, and precision measurement environments.

Accessories:
Instrument host1
CS studio software1
Power cable1
USB cable1
electrode cable1
Dummy cell1
Manual1
Accessories Optional:
Ag/AgCl reference electrode1
Glassy carbon working electrode (3mm)1
Pt wire counter electrode1
electrochemical cell 250 ml (non-sealed)1