Coulometric Karl Fischer Titrator FM-AKT-A100 Catalog

Overview

Coulometric Karl Fischer Titrator FM-AKT-A100 is a two chamber electrolysis method of titration for determination of water content in petroleum products, lubricating oils and additives by Karl Fischer reagent. Samples with water content between 1 ppm and 100% are analyzed in single measurement using alternate current polarization method of endpoint detection. Twin platinum electrode and maximum electrolysis speed of 40 μg H2O/s enables fast and precise moisture determination with very simple operation.

Specifications:

Method Karl Fischer Coulometric Titration
Measuring cell Two electrolysis measuring chambers
Amount of electrolyzed water 10 ug to 1000 ug
Measurement range 0 to 100 mg
Moisture range 1 ppm to 100%
Precision of electrolyzed water >1000 ug,0.2%
Display resolution 0.1 ug
Display 240×128 graphics dot-matrix LCD screen display
End point detection Alternate current polarization method with a twin platinum electrode
End point indication Visual display/print out
Maximum electrolysis speed 40 ug/s
Drift compensation Automatically controlled
Print format (test result) μg, mg/kg, ppm, %
Data storage 255 data with time mark
Calendar/clock Analysis time and date print out
Maximum power consumption 30 W
Power supply AC 220 V±20%, 50 Hz
Ambient temperature 10 to 35 ℃
Relative humidity ≤ 85%
Dimension 320 × 240 × 150 mm
Net weight 5 kg

Features:

  • 240×128 graphics dot-matrix LCD screen touch panel for operation
  • Built in with standards of ASTM D1533 and ASTM D6304
  • High precision detector electrode with anti-blocking property marks the end point rapidly and accurately
  • Multi-language display and print out
  • Integral high-speed thermal printer along with statistics
  • Automatic compensation of error by adopting electrolyte blank current and equilibrium point drift compensation
  • Automatic detecting function for open-circuit fault and short-circuit fault of measuring electrode
  • Displays data input parameters, sample ID numbers and time/date of analysis
  • Data storage of 255 data with time mark
  • Screen protection function: Auto screen off when machine is not in use
  • User-friendly operations

Applications:

Used for assessing water (moisture) content in petroleum and petrochemical products including oils, gasolines, solvents, and fluids as well as other products such as pharmaceuticals and cosmetics.

Accessories:
Accessories NoItemUnitQuantity
1Electrolytic cell bottle(Measuring bottle with 5 openings)Piece1
2Measuring electrodePiece1
3Electrolysis electrodePiece1
4Electrolytic cell inlet sample stopperPiece1
5Large glass ground stopperPiece1
6Small glass ground stopper (with notch)Piece1
7Small glass ground stopperPiece1
8StirrerPiece2
9Sample filling device 0.5 μlPiece1
10Sample filling device 50 μlPiece1
11Sample filling device 1 mlPiece2
12Straight drying tubePiece1
13Power linePiece1
14Vacuum greasePiece1
15ElectrolyteBottle1
16Printer paperRoll1
17Silica gel beadPocket1
18Silicone padPiece10
Fison logo