ICP Mass Spectrometer FM-ICP-B100 detects elements from Mass Range 2 to 255 amu using advanced quadrupole mass filtering. Its ultra-low background ensures unmatched trace detection accuracy. The high-temperature plasma source enables precise ionization of complex matrices. Fast multi-element scanning enhances analytical throughput and data reliability. Engineered for laboratories demanding stability, precision, and effortless performance.
| Mass Range | 2 to 255 amu |
| Test Range | greater than 10⁸ |
| Linear Range | greater than or equal to 10⁸ |
| Sensitivity | Be greater than or equal to 2 × 10⁶ cps/mg/L |
| Detection Limit | Be less than or equal to 10 ng/L |
| Resolution | 0.6 to 0.8 amu |
| SNR (Signal to Noise Ratio) | greater than or equal to 50 × 10⁶ |
| Background Noise | less than or equal to 2 cps (all mass number range) |
| Mass Axis Stability | less than or equal to 0.05 amu/24 h |
| Stability RSD | Short period: less than or equal to 3% |
| Atomizer | Quartz glass concentric atomizer, flow rate: 0.8 mL/min |
| Torch Tube | Quartz material, 1.5 mm calibre |
| ICP Source | 27.12 MHz Solid State Technology |
| Mass Flow Meters | Three units |
| Control System | Computer-based |
| Gases Controlled | 3 PC-controlled mass flow meters to control the flow of atomizing gas, auxiliary gas and plasma gas. |
| Quadrupole | Material: Molybdenum (Mo) |
| Oxide Ion | CeO⁺/Ce⁺ ≤ 3% |
| Water Circulation System Temperature Control Range | 10 to 40℃ |
| Water Circulation System Minimum Flow Velocity | 5 L / min |
| Water Circulation System Pressure Control | 0 to 600 kPa |
| Divalent Ions | ⁶⁹Ba²⁺/¹³⁸Ba⁺ less than or equal to 3% |
| Isotope Ratio | ¹⁰⁷Ag/¹⁰⁹Ag ≤ 0.3% |
| Abundance Sensitivity | less than or equal to 1 × 10ˉ⁶ low mass number |
| Multichannel Signal Analyzer | 65,000 channels |
| Software Compatibility | control instruments and accessories automatically, Windows 2000/XP/vista/win7 professional operating system (32’s or 64’s) |
| Power | 1600 W |
| Dimension | 1100 × 700 × 1000 mm |
| Weight | 400kg |
ICP Mass Spectrometer FM-ICP-B100 is ideal for environmental analysis, semiconductor quality control, food safety testing, geological surveys, and pharmaceutical trace metal quantification, offering precise elemental detection in ultra-trace levels across diverse industries.
| Accessory | Quantity |
| Glove box | 1 Pcs |
| PC cable | 4 Pcs |
| Reducing valve | 1 Pcs |
| Bellows | 2 Pcs |
| Radial spring clamp | 2 Pcs |
| Sealing ring | 2 Pcs |
| PU tube | 1 Pcs |
| Peristaltic pump head hose | 2 Pcs |
| Polyurethane hose | 1 Pcs |
| Peristaltic pump tubing | 1 Pcs |
| Exhaust pipe | 1 Pcs |
| Erthnet cable | 1 Pcs |
| Mechanical pump | 2 Pcs |
| Vacuum Clamp | 1 Pcs |
| Plastic box | 1 Pcs |
| Allen wrench | 1 Pcs |
| Ball allen wrench | 1 Pcs |
| Double-ended wrench | 3 Pcs |
| Adjustable wrench | 1 Pcs |
| Flat-blade screwdriver | 1 Pcs |
| tweezers | 1 Pcs |
| Phillips screwdriver | 2 Pcs |
| Cooling water tank | 1 Pcs |
| Document | 1 Pcs |
| Flash storage | 1 Pcs |