Our specialists will reach out shortly.

Coulometric Karl Fischer Titrator FM-AKT-A100

Coulometric Karl Fischer Titrator FM-AKT-A100

Coulometric Karl Fischer Titrator FM-AKT-A100 is a two chamber electrolysis method of titration for determination of water content in petroleum products, lubricating oils and additives by Karl Fischer reagent. Samples with water content between 1 ppm and 100% are analyzed in single measurement using alternate current polarization method of endpoint detection. Twin platinum electrode and maximum electrolysis speed of 40 μg H2O/s enables fast and precise moisture determination with very simple operation.

$7,404.00

Download Catalog

Specifications

Method Karl Fischer Coulometric Titration
Measuring cell Two electrolysis measuring chambers
Amount of electrolyzed water 10 ug to 1000 ug
Measurement range 0 to 100 mg
Moisture range 1 ppm to 100%
Precision of electrolyzed water >1000 ug,0.2%
Display resolution 0.1 ug
Display 240×128 graphics dot-matrix LCD screen display
End point detection Alternate current polarization method with a twin platinum electrode
End point indication Visual display/print out
Maximum electrolysis speed 40 ug/s
Drift compensation Automatically controlled
Print format (test result) μg, mg/kg, ppm, %
Data storage 255 data with time mark
Calendar/clock Analysis time and date print out
Maximum power consumption 30 W
Power supply AC 220 V±20%, 50 Hz
Ambient temperature 10 to 35 ℃
Relative humidity ≤ 85%
Dimension 320 × 240 × 150 mm
Net weight 5 kg

Features

  1. 240×128 graphics dot-matrix LCD screen touch panel for operation
  2. Built in with standards of ASTM D1533 and ASTM D6304
  3. High precision detector electrode with anti-blocking property marks the end point rapidly and accurately
  4. Multi-language display and print out
  5. Integral high-speed thermal printer along with statistics
  6. Automatic compensation of error by adopting electrolyte blank current and equilibrium point drift compensation
  7. Automatic detecting function for open-circuit fault and short-circuit fault of measuring electrode
  8. Displays data input parameters, sample ID numbers and time/date of analysis
  9. Data storage of 255 data with time mark
  10. Screen protection function: Auto screen off when machine is not in use
  11. User-friendly operations

Applications

  • Used for assessing water (moisture) content in petroleum and petrochemical products including oils, gasolines, solvents, and fluids as well as other products such as pharmaceuticals and cosmetics.

Accessories

  • Accessories No Item Unit Quantity
    1 Electrolytic cell bottle(Measuring bottle with 5 openings) Piece 1
    2 Measuring electrode Piece 1
    3 Electrolysis electrode Piece 1
    4 Electrolytic cell inlet sample stopper Piece 1
    5 Large glass ground stopper Piece 1
    6 Small glass ground stopper (with notch) Piece 1
    7 Small glass ground stopper Piece 1
    8 Stirrer Piece 2
    9 Sample filling device 0.5 μl Piece 1
    10 Sample filling device 50 μl Piece 1
    11 Sample filling device 1 ml Piece 2
    12 Straight drying tube Piece 1
    13 Power line Piece 1
    14 Vacuum grease Piece 1
    15 Electrolyte Bottle 1
    16 Printer paper Roll 1
    17 Silica gel bead Pocket 1
    18 Silicone pad Piece 10

Alternative Models Of Coulometric Karl Fischer Titrator

Fison Coulometric Karl Fischer Titrators detect sample moisture content based on electric current analysis. They feature auto-dispense, auto-mix and auto-detect operation. Equipped with LCD systems for easy viewing of units, titration volume, current value etc. They are built with chemical-resistant materials to withstand harsh reagents of Karl-Fischer reactions. Our Coulometric KF Titrators indirectly measure trace level water content in the range of 1µg to 1000 µg.