Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

Our specialists will reach out shortly.

Ion chromatography system FM-ICS-A102

Ion chromatography system FM-ICS-A102

Ion Chromatography System FM-ICS-A102 operates at a maximum pressure of 42 MPa (6000 psi) ensuring stable high-performance ion separation. Integrated single-chassis construction minimizes dead volume while optimizing internal fluid pathways. Full PEEK flow architecture supports wide pH compatibility with strong resistance to chemical corrosion. Built-in eluent generation and online vacuum degassing maintain consistent flow and signal stability. Designed to deliver precise analytical performance through intelligent automation and compact engineering.

$26,962.00


Download Catalog

Ion chromatography system FM-ICS-A102 - Specifications

Maximum pressure 42 MPa / 6000 Psi
Flow range 0.001 to 10.000 mL/min
Flow accuracy ≤0.1%
Flow repeatability RSD ≤0.01%
Pressure fluctuation ≤0.5%
Flow increment ≤0.001 mL/min
Materials quartz plunger, high-pressure seals, PEEK pump head; acid/alkali/organic solvent resistant and durable.
Over pressure protection automatic alarm and shutdown when pressure exceeds preset limit.
Electrically Controlled Autosampling Valve head material PEEK
Lifetime ≥100,000 switching cycles
Anion Column High-capacity anion separation column capable of analyzing F⁻, Cl⁻, Br⁻, NO₂⁻, NO₃⁻, SO₄²⁻, PO₄³⁻, ClO₂⁻, ClO₃⁻, BrO₃⁻, dichloroacetic acid, trichloroacetic acid, formate, acetate, oxalate, etc.
Cation Column High-capacity cation separation column capable of analyzing Li⁺, Na⁺, K⁺, NH₄⁺, Ca²⁺, Mg²⁺, methylamine, dimethylamine, trimethylamine, etc.
Maximum pressure of Anion and Cation Column ≥3000 psi
Flow rate of Anion and Cation Column ≥2.0 mL/min
Suppressor Factory-produced electrolytic continuously regenerated suppressor, no external regenerant or pumps required.
Suppression capacity ≥100 μeq/min
Dead volume ≤50 μL
Conductivity Detector high-sensitivity, large-capacity bipolar conductivity detector with wider detection range
Temperature compensation of Conductivity Detector ambient +5°C to 80°C
Max pressure tolerance of Conductivity Detector ≥8 MPa
Temperature control accuracy of Conductivity Detector ±0.1°C
Baseline noise of Conductivity Detector ≤0.5% FS
Baseline drift of Conductivity Detector ≤10.0% FS / 30 min
Minimum detection limit of Conductivity Detector Cl⁻ ≤0.0005 μg/mL; Li⁺ ≤0.0005 μg/mL
Qualitative repeatability of Conductivity Detector ≤0.5%
Quantitative repeatability of Conductivity Detector ≤1%
Temperature Control System Dual-isolation, internal circulation, high-precision temperature control system with independent column oven and shared oven for detector and suppressor, ensuring high stability.
Power consumption 1200 W
Power supply 220 V 50 Hz
Dimension (W × D × H) 518 × 422 × 768 mm
Packaging dimension (W × D × H) 600 × 500 × 800 mm
Net weight 52 kg
Gross weight 62 kg

Ion chromatography system FM-ICS-A102 - Features

  1. Leak alarm protection
  2. One-click operation
  3. Automatic pump rinsing
  4. Timed shutdown control
  5. Dual-channel acquisition

Ion chromatography system FM-ICS-A102 - Applications

  • Ion Chromatography System FM-ICS-A102 is used for simultaneous anion and cation analysis in environmental laboratories, pharmaceutical quality control, food and beverage testing, chemical research facilities, and academic or industrial analytical laboratories requiring high-precision ionic analysis.

Ion chromatography system FM-ICS-A102 - Accessories Optional

  • Accessory Quantity 
    Anion column1 set
    Cation Column1 set
    Four-stage online degassing1 set
    Autosampler 120wells1 set
    Anion eluent1 set
    MSA Built-in Eluent Generator1 set

Ion chromatography system FM-ICS-A102 - Autosampler Optional

  • Autosampler specifications:

    3D autosampler120 × 1.5 mL sample positions
    Injection repeatabilityRSD ≤0.5% (full-loop injection)
    Sample residue≤0.01% (with specified needle-wash procedure)
    Dual operationmanual panel control and software control
    Optional configurationone 10-port valve for simultaneous dual-channel injection

Alternative Models Of Ion Chromatography