Automatic Chemistry Analyzer FM-ACA-B201 delivers 300 tests per hour with a wide assay range. Supports photometric and turbidimetric methods for accurate, high-throughput diagnostics. Features efficient reagent management to reduce interruptions. Touchscreen interface simplifies operation. Compact layout fits smoothly into diverse lab settings.
$10,500.00
| Sample Volume | 2 to 30 µl (0.1 µl step) |
| Throughput | 300 tests/hour |
| Sample Dilution | Automatic |
| Sample Positions | 40 pcs |
| Reagent Positions | 80 pcs |
| Reagent Volume | 20 to 300 µl (1 µl step) |
| Water Consumption | 12 L/h |
| Analysis method | One-point end, Two-point end, Fixed-Time, Kinetics |
| Temperature | 2 to 14°C |
| Reusable Cuvettes | 90 pcs |
| Reaction volume | 20 to 30µL |
| Reaction time | 10 minutes |
| Reaction temperature | 37+0.1°C |
| Light source | Halogen lamp |
| Wavelength | 340 to 700 nm |
| Absorbance range | 0. to 4.0 Abs |
| Resolution | 0.0001 Abs |
| Calibration | Linear and non-linear |
| Mixer | Independent mixer |
| Washing System | Automatic 3 to 5 step washing |
| Interface | USB |
| Operation system | Windows XP, Windows 7, Windows 8 |
| Probe Features | Automatic cleaning, liquid level detection, collision protection, Automatic depth adjusting |
| Power consumption | 650 VA |
| Power supply | 100 to 220 V, 50/60 Hz |
1: How does automatic re-run enhance testing efficiency in FM-ACA-B201?
It identifies and retests questionable results without delay, maintaining workflow continuity and reducing manual rechecks.
2: What impact does clot detection have on analyzer performance?
It prevents sample-related interruptions, protecting internal components and ensuring consistent, accurate throughput.
3: How does FM-ACA-B201’s barcode scanning support regulatory compliance?
It automates sample and reagent identification, ensuring traceability for audits and minimizing labeling errors.
4: In what way does LIS connectivity with FM-ACA-B201 improve lab operations?
Enables seamless test ordering and result reporting, reducing transcription errors and accelerating diagnostic turnaround.
5: How does real-time quality control in FM-ACA-B201 ensure result accuracy?
It monitors analytical stability continuously, detecting deviations early to prevent inaccurate reporting.
Fison Automatic Chemistry Analyzer performs high throughput testing in short amount of time. Their automated sampling minimizes manual errors. They incorporate spectrophotometric and ion-selective methods for sample analysis. Integration with cost effective, thermal printer accelerates diagnosis of results. Fison offers Automatic Chemistry Analyzer having capacity to perform 400, 800 and 1200 tests per hour.