Automatic Chemistry Analyzer FM-ACA-B202 performs up to 400 tests per hour, supporting both clinical and emergency workflows. Features include a high-capacity sample tray, minimal reagent consumption, and real-time clot detection. Integrated ISE module enhances test versatility, covering electrolytes alongside standard biochemistry panels. Refrigerated reagent compartment and auto-calibration ensure consistent performance and accuracy.
$15,400.00
| Sample Volume | 2 to 30 µl (0.1 µl step) |
| Throughput | 400 tests/hour |
| Sample Dilution | Automatic |
| Sample Positions | 120 pcs |
| Reagent Positions | 90 pcs |
| Reagent Volume | 20 to 300 µl (1 µl step) |
| Water Consumption | 15 L/h |
| Analysis method | One-point end, Two-point end, Fixed-Time, Kinetics |
| Temperature | 2 to 14°C |
| Reusable Cuvettes | 90 pcs |
| Reaction volume | 150 to 350µL |
| Reaction time | 10 minutes |
| Reaction temperature | 37+0.1°C |
| Light source | Halogen lamp |
| Wavelength | 340 to 700 nm |
| Absorbance range | 0. to 4.0 Abs |
| Resolution | 0.0001 Abs |
| Calibration | Linear and non-linear |
| Mixer | Independent mixer |
| Washing System | Automatic 2 to 6 step washing |
| Interface | USB |
| Operation system | Windows XP, Windows 7, Windows 8 |
| Probe Features | Automatic cleaning, liquid level detection, collision protection, Automatic depth adjusting |
| Power consumption | 1000 VA |
| Power supply | 110 to 220 V, 50/60 Hz |
| Dimension (L×W×H) | 1065 × 745 × 1120 mm |
| Net Weight | Less than 23 kg |
1: Why is continuous access important in a high-throughput analyzer like FM-ACA-B202?
It enables uninterrupted workflows by allowing STAT or late-arriving samples to be loaded without halting routine testing, reducing turnaround delays.
2: How does FM-ACA-B202 ensure reliable performance with minimal sample volume?
Advanced liquid-level sensing and clot detection maintain precision even with 2 µL samples, reducing redraws and preserving sample integrity.
3: What role does automated maintenance play in sustaining analyzer uptime?
Features like cuvette washing, probe cleaning, and real-time system diagnostics prevent buildup-related errors and reduce manual servicing interruptions.
4: How does the analyzer adapt to variable sample conditions like hemolysis or lipemia?
It uses dual-wavelength photometry and intelligent rerun logic to detect and compensate for interferences, ensuring valid results.
5: In what ways does FM-ACA-B202 support regulatory audits and traceability?
The system logs QC, calibration, and error records in encrypted format, fully traceable and exportable via LIS for ISO 15189 and CE-IVDR compliance.
Fison Automatic Chemistry Analyzer performs high throughput testing in short amount of time. Their automated sampling minimizes manual errors. They incorporate spectrophotometric and ion-selective methods for sample analysis. Integration with cost effective, thermal printer accelerates diagnosis of results. Fison offers Automatic Chemistry Analyzer having capacity to perform 400, 800 and 1200 tests per hour.