Automatic Potentiometric Titrator

Fison Automatic Potentiometric Titrator are benchtop units to determine sample quality. They are equipped with multiple electrodes for high throughput measurements. Their fully automated operation allows for remote process control and monitoring. They are integrated with advanced software for data documentation and analysis. Our Automatic Potentiometric Titrators are built with several titre modes for versatile functioning.

Testing Method

Titration modes

pH Measuring range

Potential Measurement Range

Titration Types

Fully Automatic Potentiometric Titrator FM-APT-A100

  • Testing Method : Burette Titration method
  • Analysis parameters : pH, mV, temperature value
  • mV/pH Potential electrode interface :
    Measurement range mV: -2500.0 to +2500 mV
    pH: -20.000 to +20.000 pH
    Temperature 0 to 100°C
    Resolution mV: 0.1 mV
    pH: 0.001 pH
    Accuracy mV: 0.1. mV
    pH: 0.003 pH
    Temperature: ± 0.1°C
  • Maximum titration station : 6
Catalog

Automatic Potentiometric Titrator FM-APT-A201

  • Titration mode : Acid-base titration, Redox titration, Precipitation titration, Complexometric titration, non-aqueous
  • Temperature Measurement Range : - 5 to 120 °C
  • Temperature measurement accuracy : ± 0.1 ℃
  • Measuring range : pH value: -20.000 PH to +20.000 PH
    mV value: -2000.0 MV to +2000.0 MV
Catalog

Automatic Potentiometric Titrator FM-APT-A301

  • Potential Measurement Range : 0 to ± 2000 mV
  • Basic Error of Electronic Unit : 0.1% ± 0.5 mV of full reading
  • Input Impedance : Ri ≥ 1 × 10 ^ 12 Ω
  • Burette Volume : 10 ml
Catalog
Automatic Potentiometric Titrator FM-APT-A101
  • Titration Types : Potentiometric titration
    Polarization current titration
  • Measurement Modes : Measurement Mode (MEAS: pH, mV, T), Calibration Mode (CAL: pH), Endpoint Setting Mode (SET), Method Mode (MET: Equal Volume Titration, Second-Order Derivative Chloride Ion Measurement), Dynamic Titration Mode
  • Analysis Methods : Acid-base, Prescription, Non-aqueous, Complexometric, Permanent-stop titrations
  • Measurement Range : 0.01 mg to 50 mg of KOH / g
    mV: (-2000 to 2000) mV
    pH: (-20 to 20) pH
    Temp: (-5 to 120) °C
Catalog
Automatic Potentiometric Titrator FM-APT-A200
  • pH Measuring range : 0.00 to 14.00 pH
  • mV Measuring range : -1800.0 to 1800.0 mV
  • Temperature Span : -5.0 to 105.0 °C
  • pH precision : 0.01pH
Catalog

Automatic Potentiometric Titrator FM-APT-A300

  • Titration modes : Pre-titrations, Preset end point titration, Blank titrations, Manual titrations, Macro titration, Micro titration, Volume setting titrations, Stored titration
  • Analysis methods : Acid-base Titration, Oxidation-reduction titration, Precipitation titration, Complexometric, Non-aqueous titration
  • Measurement Range :
    pH value: 0.00 to 14.00 pH
    mV value: -1800.0 to 1800.0 mV
    Temperature value: -5.0 to 105.0 °C
  • Resolution :
    pH value: 0.01 pH
    mV value: 0.1 mV
    Temperature value: 0.1°C
Catalog