Automatic Tissue Processor FM-ATP-A102 is engineered with a 125-cassette load. It has a 2200 mL tank capacity, ensuring high efficiency and uninterrupted tissue processing. Our system combines advanced programmability with fully sealed operations for consistent results. It is ideal for high-throughput labs seeking precision and automation.
$4,950.00
Specifications
Capacity | 2200mL per tank |
Basket Capacity | 125 cassettes |
Tanks | 12 |
Wax Cylinders | 3 |
Temperature | Up to 99°C |
Temperature Accuracy | ±1°C |
Tank Processing Time | 0 to 24 hours |
Cylinder Dwell Time | 45 to 100 sec |
Stirring Frequency | 0–5 times/min (recommended: 3 times/min) |
Tissue Protection Cylinder Position | 7th tank |
Program Capacity | 16 editable programs |
Processing Time | 0 to 99 hours Adjustable |
Power Backup | 4 to 6 hours |
Power Consumption | ≤ 500W |
Power Supply | AC220V ±10%, 50Hz ±10% |
Dimensions (L×W×H) | 1250×410×560mm |
Package Dimensions | 1330× 540× 740mm |
Net weight | 82kg |
Gross Weight | 107kg |
Features
Applications
Frequently Asked Question
1: What makes the Automatic Tissue Processor FM-ATP-A102 suitable for high-volume labs?
Automatic Tissue Processor FM-ATP-A102 has a 2200 ml tank capacity and the ability to process up to 125 cassettes in a single cycle, making it perfect for high-throughput tissue processing in busy histopathology settings.
2: How does the power backup system protect samples during outages in Automatic Tissue Processor FM-ATP-A102?
In Automatic Tissue Processor FM-ATP-A102, if power is lost, the system automatically switches to its internal battery (4–6 hours backup). If the wax bath is not heated enough, samples are returned to the protection tank, preventing any tissue damage.
3: In Automatic Tissue Processor FM-ATP-A102, can I adjust or monitor the program while running?
Yes, Automatic Tissue Processor FM-ATP-A102 displays real-time parameters like program steps, heating status, and temperature. You can also add new specimens or adjust wax warming during operation.
4: Is Automatic Tissue Processor FM-ATP-A102 safe and environmentally friendly?
Absolutely. Automatic Tissue Processor FM-ATP-A102 features a fully sealed dehydration system and an external exhaust outlet to ensure lab safety and environmental compliance by minimizing reagent fumes.
5: In Automatic Tissue Processor FM-ATP-A102, can I pre-schedule tissue processing in advance?
Yes, you can program the system to start automatically at any time, even days or months in advance, supporting lab automation and off-hour processing.
Fison’s Automatic Tissue Processors are advanced laboratory instruments engineered for efficient, precise, and safe tissue dehydration, clearing, and paraffin infiltration. It is designed to accommodate 100, 200, or 300 cassettes per run. Our systems offer multiple retort and reagent volumes with built-in temperature control and programmable cycles. The sealed fluid exchange mechanism prevents reagent loss, reduces contamination, and ensures uniform sample processing. With multiple user-defined programs and an optional power-off recovery function, these processors feature fully sealed operation, intelligent vacuum/pressure modes, and advanced scheduling options ideal for clinical pathology, biomedical research, and pharmaceutical laboratories.