Chemiluminescent Immunoassay Analyzer FM-CLA-A200 delivers a throughput of 32 tests per hour, making it suitable for low to medium diagnostics workload. It comes with single-serving reagent strips for minimal reagent waste and zero cross-contamination. Its maintenance-free magnetic separation technology enhances reliability and reduces downtime. Our analyzer includes an LCD touchscreen for intuitive operation with real-time monitoring.
$6,562.00
| Throughput | 32 tests per hour |
| Reagent Positions | Single chamber 8 channels |
| Chamber Operation | Independent |
| Reagent Strip | Single |
| Reagent Use | Single-use, Zero Waste Design |
| Identification | Automatic |
| Humidity | No Effect |
| Reaction time | 15 minutes |
| Precision | CV ≤ 5% |
| Integration | LCD touchscreen, Built-in PC And Printer |
| Dimensions (L×W×H) | 350×550×550 mm |
| Weight | 36 kg |
1: How do Single-Serving strips in Chemiluminescent Immunoassay Analyzer FM-CLA-A200 improve assay precision at low concentrations?
Chemiluminescent Immunoassay Analyzer FM-CLA-A200 reduces cross-contamination and reagent exposure, maintaining inter-assay CVs below 4% at sub-picogram levels.
2: How does the Chemiluminescent Immunoassay Analyzer FM-CLA-A200 ensure lot-to-lot reagent consistency without full recalibration?
A bridging algorithm compares new lot results to historical QC means and adjusts calibration if within limits in Chemiluminescent Immunoassay Analyzer FM-CLA-A200.
3: What enables Chemiluminescent Immunoassay Analyzer FM-CLA-A200 five-minute cycle per test?
Chemiluminescent Immunoassay Analyzer FM-CLA-A200 delivers fast enzyme-substrate kinetics and optimized chemiluminescent yield drive quick signal generation with optional method tuning.
4: How is the high-dose hook effect prevented in Chemiluminescent Immunoassay Analyzer FM-CLA-A200?
Auto-reflex dilution in Chemiluminescent Immunoassay Analyzer FM-CLA-A200 triggered when photon counts exceed thresholds, preserving linearity in high concentrations.
5: How does Chemiluminescent Immunoassay Analyzer FM-CLA-A200 maintain linearity at high analyte concentrations?
Chemiluminescent Immunoassay Analyzer FM-CLA-A200 ensures linearity by automatically initiating reflex dilution if photon signal exceeds defined limits, preventing hook effect interference.
Fison Chemiluminescent Immunoassay Analyzers are designed to detect diseases by separating and effective isolation, components using magnetic particles. These offer a maximum throughput of 180 tests per hour and process samples from 10 to 200 µL. The analyzers provide real-time updates, allowing users to continuously monitor test progress. They are equipped with safety alarms to ensure smooth operation and triple magnetic separation cleaning technology. Our immunoassay analyzers are used for clinical diagnosis, cancer screening, hormone testing, and drug monitoring.