Fison ESR analyzer FM-ESR-A100 reads red blood cell sedimentation in vacuum blood collection tubes using infrared detection and reports Westergren ESR values in mm/h. This erythrocyte sedimentation rate analyzer has 40 channels for testing 40 samples at once and completes up to 80 tests per hour at the 30-minute setting, with 30-minute or 60-minute analysis time selectable. Samples can be added at any time without waiting for a full batch, and results are automatically corrected to 18 °C. The measurement range is 0 to 150 mm/h, and a built-in thermal printer prints the results. The analyzer measures how fast red blood cells settle in blood samples and reports the result as an ESR value.
$1,832.00
| Measurement method | Infrared detection |
| Analysis result | Westergren ESR value (mm/h) |
| Throughput | Max. 80 tests/hour |
| Analysis channels | 40 (up to 40 samples tested at the same time) |
| Loading type | Load samples at any time, measure at any time |
| Analysis time | 30 min or 60 min (selectable) |
| Sampling interval | 3 min |
| Measurement range | 0 to 150 mm/h |
| Result resolution | 1 mm/1 h and 1 mm/2 h |
| Reading accuracy | ±0.1 mm |
| Repeatability | 0 to 10 mm/h: SD ≤ 1.5 mm/h; above 10 mm/h: CV ≤ 8% |
| Channel consistency | 0 to 10 mm/h: SD ≤ 1.5 mm/h; above 10 mm/h: CV ≤ 8% |
| Temperature compensation | Results automatically corrected to 18 °C |
| Blood level range | 46 to 64 mm |
| HCT range | 0.2 to 1.0 |
| Display | 7-inch color LCD touch screen |
| Printer | Built-in thermal printer |
| Communication interface | Type-C, USB |
| Power supply | AC 110 to 220 V, 50/60 Hz |
| External size (W × D × H) | 284 × 355 × 208 mm |
| Packaging size (W × D × H) | 339 × 544 × 249 mm |
| Net weight | 6.3 kg |
| Gross weight | 9.4 kg |
ESR Analyzer FM-ESR-A100 is used in hospital laboratories, medical laboratories, research institutes and disease control centers to test the erythrocyte sedimentation rate of blood samples. It replaces the manual steps of the Westergren method with automatic infrared detection, so laboratories can report ESR results faster and with less sample handling.
Name | Qty |
User manual | 1 |
Certification | 1 |
Disposable negative pressure blood collection vessel | 100 |
Printer paper | 1 |
Fuse | 2 |
Type-C data cable | 1 |
RVV power cord | 1 |
Fison ESR Analyzer measures erythrocyte sedimentation rate by infrared detection, with each channel tracking red blood cell sedimentation and reporting its own Westergren ESR value. The 40 analysis channels test up to 40 samples at the same time, and throughput reaches up to 80 tests/hour, so full batches are analyzed in parallel. As a sed rate machine, the analyzer automates ESR readout and returns a Westergren result for every sample in the batch.