Micro Spectrophotometer FM-MS-A104 offers a wavelength range from 180 to 910 nm across a broad spectrum. It requires a minimal sample volume ranging from 0.5 μL to 2 μL, with 2 μL recommended for optimal results. It can accommodate a fluorometer sample volume range of 1 to 20 μL, allowing flexibility for various fluorescence measurements. It features an intuitive touchscreen interface, enabling easy operation and quick access to all functions.
$9,100.00
| Sample Volume | 0.5 μL to 2 μL (Recommended: 2 μL) |
| Wavelength Range | 180 to 910 nm |
| Nucleic Acid Detection Range | dsDNA: 2 to 37,500 ng/μL ssDNA: 1.32 to 24,750 ng/μL RNA: 1.6 to 30,000 ng/μL |
| Protein Detection Range | A280: 0.04 to 750 mg/mL BSA: 0.06 to 1,119 mg/mL IgG: 0.03 to 547 mg/mL Lysozyme: 0.015 to 284 mg/mL |
| Absorbance Range (10 mm eq.) | 0.04 to 750 (at 260 nm) |
| Path Length Options | 0.02, 0.03, 0.1, 0.2, 1 mm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Precision | ±0.2 nm |
| Absorbance Precision | 0.002 Abs (1 mm pathlength) |
| Spectral Resolution | ≤ 1.5 nm (FWHM @ Hg 253.7 nm) |
| Absorbance Accuracy | ±1% (7.332 at 260 nm) |
| Light Source | Xenon flash lamp (>10⁹ flashes) + LED (Fluorometer) |
| Detector | 2048-element linear CMOS array |
| Sample Pedestal Material | 304 Stainless steel and Quartz fiber |
| Measurement Time | < 6 seconds (Absorbance), 3 seconds (Fluorometer) |
| OD600 Absorbance Range | 0 to 4.000 Abs |
| OD600 Stability | ≤0.5% (0 to 3 Abs), ≤1.5% (3 to 4 Abs) |
| OD600 Repeatability | ≤0.5% (0 to 3 Abs), ≤1.5% (3 to 4 Abs) |
| OD600 Accuracy | ≤0.005 Abs (0 to 2), ≤1% (2 to 3), ≤2% (3 to 4) |
| Heating | Up to 37°C |
| Stirring Speed | 100 to 900 rpm |
| Fluorometer Sample Volume | 1 to 20 μL |
| Fluorometer Repeatability | < 1.5% |
| Fluorometer Linear Dynamic Range | R² ≥ 0.995 |
| Fluorometer Sensitivity | 0.5 pg/μL dsDNA |
| Fluorometer Light Source | LED |
| Fluorometer Excitation Wavelengths | 470/625 nm (Standard), 365/525 nm (Optional) |
| Fluorometer Emission Wavelengths | 525/690 nm (Standard), 460/620 nm (Optional) |
| Fluorometer Concentration Range | dsDNA HS: 0.005 to 120 ng/μL dsDNA BR: 0.2 to 2000 ng/μL Oligo: 0.01 to 240 ng/μL RNA: 0.2 to 200 ng/μL MicroRNA: 0.025 to 150 ng/μL Protein: 12.5 μg/mL to 5 mg/mL Protein BR: 0.1 to 20 mg/mL |
| Power Consumption (Work/Standby) | 48 W / < 6.5 W |
| Power Adaptor | DC 12, 4A |
| Dimensions (W×D×H) | 300 × 232 × 196 mm |
| Weight | 4.2 kg |
| Accessory | Quantity |
| Cuvette | 2 (45×12.5×12.5) |
| Stirrer | 2 (3×6 mm) |
| U - disk | 1 |
| Thermal printing paper | 4 rolls (57×20, thickness of 0.06 to 0.08) |
| Dust cover | 1 |
Fison Micro Spectrophotometer features motorized stages that enable precise mapping and imaging, significantly enhancing efficiency and reproducibility in sample analysis. They provide data analysis tools that facilitate spectrum interpretation, mapping, and exporting. Their advanced optical microscopy supports real-time imaging alongside spectral analysis. The spectrophotometer speeds up analysis by quickly capturing spectra across multiple wavelengths. Our Spectrophotometer is designed with advanced detectors to ensure precise measurements, even in low-light conditions.