Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

Our specialists will reach out shortly.

Class II A2 Biological Safety Cabinet FM-BSC-A406 Class II A2 Biological Safety Cabinet FM-BSC-A406 Class II A2 Biological Safety Cabinet FM-BSC-A406

Class II A2 Biological Safety Cabinet FM-BSC-A406

Class II Biosafety Cabinet FM-BSC-A406 (1.2m / 4 ft, 0.72 m² work area) delivers Class II A2 protection with an inflow velocity of 0.53 m/s and downflow of 0.33 m/s. Its ULPA filtration (>99.999% efficiency) safeguards samples and operators, while the LCD control panel provides real-time performance monitoring. The tilt-front design improves comfort, and the stainless-steel chamber ensures durability. With low energy use, it is ideal for biotechnology, pharmaceutical, and clinical labs. 

$9,436.00

Download Catalog

Class II A2 Biological Safety Cabinet FM-BSC-A406 - Specifications

Average Airflow Velocity Inflow: 0.53±0.025m/s (104.3±4.92fpm)
Downflow: 0.35±0.025m/s (68.9±4.92fpm)
Airflow Volume – Inflow 477m³/h (281cfm)
Airflow Volume – Downflow 956m³/h (556cfm)
Airflow Volume – Exhaust 477m³/h (281cfm)
ULPA Filter Typical Efficiency Filters provide 99.99995% typical efficiency for particle size of 0.1 to 0.2 microns
Biosafety Protection Test – Personnel KI-Discus containment and microbiological testing is performed
Biosafety Protection Test – Product ≤5 CFU
Biosafety Protection Test - Cross-contamination ≤2 CFU
Sound Emission (Typical) - NSF/ANSI 49 <62 Dba
Sound Emission (Typical) - EN 12469 ≤59 dBA
Fluorescent Light Intensity ≥650 Lux (≥60 foot candles)
Excellent light distribution Yes
RMS ≤5 μm
Cabinet Construction - Main Body 1.2mm (0.05'') steel with white oven-baked epoxy-polyester
Cabinet Construction - Work Zone 1.5mm (0.06'') stainless steel, type 304
Cabinet Construction - Side Walls 1.5mm (0.06'') stainless steel, type 304
Electrical sliding windows Option Yes
Window material Hardened/laminated safety glass
Electrical - Cabinet Full Load Amp (FLA) 2A
Electrical – Fuses 10A
Electrical - Cabinet Nominal Power 452W
Electrical - Optional Outlets FLA 5A
Electrical - Total Cabinet FLA 7A
Power Supply 220V/50Hz, 110V60Hz
Nominal Size 1.2 meters (4')
Internal Work Area, Space 0.72m² (7.8 sq.ft)
Internal Work Area, Dimensions (W×D×H) 1250×575×625mm (49.2''×22.6''×24.6'')
External Dimensions with Base Stand (W×D×H) 1340×790×2130mm (52.8''×31.1''×83.9'')
Packaging Dimensions (W×D×H) 1425×945×1717mm (56.1''×37.2''×67.3'')
Shipping Volume, Maximum 2.30m³ (81.2 cu.ft)
Net Weight 225kg (496lbs)
Gross Weight 295kg (650lbs)

Class II A2 Biological Safety Cabinet FM-BSC-A406 - Features

  1. Ergonomic Tilt Design
  2. Explosion-Proof Safety Glass
  3. Flow-Safe Airflow
  4. Energy-Saving Operation
  5. Quiet Blower System

Class II A2 Biological Safety Cabinet FM-BSC-A406 - Applications

  • Class II A2 Biological Safety Cabinet FM-BSC-A406 is widely used in biotechnology, microbiology, pharmaceutical, and clinical laboratories for safe handling of infectious agents, tissue culture, and sensitive sample preparation under Biosafety Levels 1–3.

Class II A2 Biological Safety Cabinet FM-BSC-A406 - Accessories Optional

  • 1

    Main filter and Exhaust filter 

    2

     Exhaust connector w/o blower 

    3

     Exhaust connector with blower 

    4

     Fixed floor stand (1)

    5

     Mobile floor stand 

    6

     Fixed floor stand (low) 

    7

     Fixed floor stand (2)

    8

     Vacuum/O2/Air/N2 tap (1)

    9

     Water tap (1)

    10

     Burning gas tap (1)

    11

     Loop heat sterilizer (Φ=37mm) (1)

    12

     Loop heat sterilizer (Φ=16mm) (1)

    13

     Vacuum/O2/Air/N2 tap (2)

    14

     Water tap (2)

    15

     Burning gas tap (2)

    16

     Foot-control switch 

    17

     Mobile UV lamp 

    18

     Loop heat sterilizer (Φ=37mm) (2)

    19

     Loop heat sterilizer (Φ=16mm) (2)

Frequently Asked Question

1: How does the FM-BSC-A406 improve laboratory safety?

The FM-BSC-A406 uses ULPA filtration with >99.999% efficiency and precise airflow control to protect operators, samples, and the environment from contamination.

2: What makes the FM-BSC-A406 energy-efficient?

It is equipped with a low-noise, energy-saving blower and optimized airflow design, reducing power consumption while maintaining safe operating conditions.

3: What certifications does the FM-BSC-A406 comply with?

The FM-BSC-A406 complies with international biosafety standards such as EN 12469 and NSF/ANSI 49, ensuring reliable global laboratory use.

4: How easy is it to maintain the Class II A2 Biosafety Cabinet FM-BSC-A406?

The cabinet features a stainless-steel interior for easy cleaning, front access for filter replacement, and clear LCD alerts for service reminders.

Alternative Models Of Class II Biosafety Cabinet

Fison Class II Biosafety Cabinets offer personnel, product, and environmental protection by preventing contamination during biological sample handling. They are equipped with a laminar airflow design that maintains continuous airflow for optimal sample protection. Our cabinets feature a HEPA filtration system that effectively removes airborne contaminants. They provide negative pressure to prevent hazardous particle escape. These units deliver energy-efficient operation with optimized airflow and lighting for safety and performance.