Fison Fluorescence Spectrophotometer FM-FS-B100 delivers high-sensitivity fluorescence analysis with a 200 to 900 nm excitation wavelength range and a 150 W xenon lamp. The system features wavelength accuracy of ±0.4 nm, S/N ≥350 (P-P), and scan speeds up to 60000 nm/min for rapid spectral acquisition. Dual-beam monitoring, an integrated octave filter, adjustable excitation and emission slits, and advanced optical monitoring ensure stable, precise, and consistent fluorescence measurements.
$26,812.00
| Excitation Wavelength | 200 nm to 900 nm |
| Excitation Source | 150 W Xenon Lamp |
| Excitation Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
| Emission Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
| Wavelength Accuracy | ± 0.4 nm |
| Wavelength Repeatability | ≤ 0.2 nm |
| Signal-to-Noise Ratio | S/N ≥ 350 (P-P), S/N ≥ 1000 (RMS) |
| Limit | ≤ 5 × 10 -11 g /ml(Quinine Sulfate Solution) |
| Linearity | γ ≥ 0.995 |
| Peak Repeatability | ≤ 1.5 % |
| Wavelength Scan Speed | Multi-speed Level, Maximum at 60000 nm / min |
| Minimum sample size | 0.5 mL (Using a standard 10 mm square sample cell) |
| Octave filter | Build in Octave filter |
| Photometric Quantity Range | -9999 to 9999 |
| Response Time | Auto adjust (0.02 s, 0.1 s, 0.5 s, 1 s, 2 s, 4 s, 8 s) |
| Data Transportation | USB 2.0 |
| Power | 200 W |
| Power Supply | AC 220 V / 50 Hz, 110 V / 60 Hz |
| Dimension | 610×460×365 mm |
| Net Weight | 21 kg |
| Gross Weight | 26 kg |
Fluorescence Spectrophotometer FM-FS-B100 is used for qualitative and quantitative fluorescence analysis in chemical research, biomedicine, environmental monitoring, material science, and academic laboratories.
Accessory |
Multi-function adapter |
Membrane sample holder |
200µL microcentrifuge tube holder |
Powder sample holder |
Peltier temperature control holder |
Sample cell jacket |
Up conversion laser head holder |
Fluorescence Quantum Yield accessory |
500 µL Microscale quartz cuvette |
200 µL Microscale quartz cuvette |
Glass cuvette 4-side-clear |
Quartz cuvette 4-side-clear |
10mm cell holder adapter |
Double frequency filter |
Auto Polarization Filter (Visible:400 to 700nm) |
Auto Polarization Filter (UV-visible: 250 to 1000nm) |
Xenon Lamp |
Fison Fluorescence Spectrophotometers deliver high-sensitivity fluorescence measurements for detecting low-concentration samples with accuracy and consistency. Available with LED or 150 W xenon lamp light sources, these systems support excitation and emission wavelength ranges up to 200 nm to 900 nm for versatile analytical workflows. An advanced optical system, automatic wavelength adjustment, and user-friendly digital controls ensure precise fluorescence analysis.