Page content is loading
×

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

Our specialists will reach out shortly.

Gas Chromatography FM-GC-A100

Gas Chromatography FM-GC-A100

Gas chromatography FM-GC-A100 controls temperatures precisely from RT + 5°C to 450°C. It features a high-precision gas flow control system (EPC) for accuracy. It includes self-protection for gas circuit failure and automatic ignition. Innovative sampler design prevents sample sticking to the surface. Various injection methods like headspace sampling, thermal desorption analysis, and liquid automatic sampling are enabled. It can start analyses automatically at set times. The unit offers a user-friendly interface with a color widescreen and unique touch keys. Its modular design allows easy upgrades and compatibility with detectors such as FID, TCD, ECD, FPD, and NPD.

$7,330.00


Download Catalog

Gas Chromatography FM-GC-A100 - Specifications

Oven Temperature Range RT + 2 to 450 °C
Temperature Control Accuracy 0.01 °C
Temperature Program ≥ 99 levels, 100 platforms
Maximum Heating Rate 250 °C/min
Temperature Control System 8-channel independent temperature control with automatic temperature protection function
Selectable Setector Types FID, TCD, FPD, ECD, NPD (3 different types can be installed simultaneously)
Flame ionization detector (FID) Operating temperature: 450 °C; detection limit: ≤ 1.1 pg C/s (n-hexadecane); baseline drift (30 min): ≤ 2 × 10⁻¹³ A; baseline noise: ≤ 2 × 10⁻¹⁴ A; dynamic linear range: ≥ 10⁷; automatic ignition function
Thermal Conductivity Detector (TCD) Sensitivity: ≥ 10,000 mV·mL/mg; baseline drift (30 min): ≤ 0.2 mV; baseline noise: ≤ 0.05 mV; dynamic linear range: ≥ 10⁵; safety protection: gas bridging current protection function
Flame Photometric Detector (FPD) Maximum operating temperature: 450 °C; limits of detection: P ≤ 80 fg/s, S ≤ 8 pg/s (methyl parathion); dynamic linear range: P ≥ 10³, S ≥ 10²; automatic ignition function
Electron Capture Detector (ECD) Radioactive source: 63Ni; maximum operating temperature: 400 °C; limit of detection: ≤ 1.0 × 10⁻¹⁴ g/mL (γ-666); dynamic linear range: ≥ 10⁴
Nitrogen-Phosphorus Detector (NPD) Maximum operating temperature: 400 °C; limits of detection: N ≤ 1 × 10⁻¹² g(N)/s (azobenzene), P ≤ 5 × 10⁻¹³ g(P)/s (malathion); dynamic linear range: N ≥ 10³, P ≥ 10³
Power Supply AC 220 V, 50/60 Hz
Product Dimensions (W × D × H) 670 × 580 × 500 mm
Packing Dimensions (W × D × H) 840 × 720 × 750 mm
Net Weight 60 kg
Gross Weight 73 kg

Gas Chromatography FM-GC-A100 - Features

  • Gas chromatography offers efficiency, stability, and user-friendly operation
  • 16-phase temperature program at 40°C/min
  • Equipped with Brain Chrom workstation for data processing
  • Built-in Modbus/TCP server for easy connection to DCS
  • Injection types include packed column injection and capillary column injection
  • Flow setting range of 0 to 1000 ml/min
  • Sampling valve can be equipped with multiple imported automatic control valves
  • Supports 1 to 4 inlets, allowing up to 3 capillary column inlets for injection

Gas Chromatography FM-GC-A100 - Applications

Gas chromatography is employed across diverse sectors for applications such as environmental monitoring, petrochemical analysis, pharmaceutical research, food and beverage testing, forensic investigations, chemical research, clinical diagnostics, material analysis, quality control, and research and development

Gas Chromatography FM-GC-A100 - Standard Accessories

  • FID Detector
    Chromatography workstation software
    Capillary Sampler

Gas Chromatography FM-GC-A100 - Accessories Optional

  • Accessories NameSpecification
    Sample Injection System 
    Thermal Conductivity meter(TCD)Sensitivity : > 5000 mv.ml /mg
    ( 50 mg /ml toluene -benzene solution )
    Temperature : 400°C
    Baseline drift : ≤ 0.1 m V /30 min
    Linear range : ≥ 105 ( ± 10 % )
    Electron Capture Detector ( ECD )Detection limit : ≤ 1 × 10 -14 g / ml
    ( Sample : n -hexadecane – δ 666 )
    Linear Range : ≥ 10 4
    Flame Photometric Detector ( FPD )Detection limit : ≤5 × 10 -12g/s (S of 10 ng/ul methyl parathion-ethanol solution)
    Detection limit : ≤ 4×10 -12 (P of 10 ng/ul methyl parathion-ethanol solution)
    Linear range (S): ≥ 103
    Linear range ( P) : ≥ 10 4
    Nitrogen and Phosphorus Detector ( NPD )Detection limit : ≤ 1 × 10 -12g/s(Azobenzene)
    Detection limit : ≤ 1 × 10-12 (Marla sulfur phosphorous)
    Linear range : ≥ 10 3

Gas Chromatograph