Fison Horizontal Autoclave FM-HA-B103 features a 1000 L stainless steel chamber with an operating temperature of up to 150°C and a maximum working pressure of 0.25 MPa for high-capacity steam sterilization. Equipped with automatic controls, an advanced vacuum system, integrated safety features, precise temperature regulation, and a durable pressure vessel, it supports efficient sterilization cycles with consistent performance.
$30,375.00
| Capacity | 1000 L |
| Operating Temperature | 150 ℃ |
| Maximum Operating Temperature | 138 ℃ |
| Maximum Working Pressure | 0.25 MPa |
| Inner Chamber Design Pressure | -0.1 to 0.3 MPa |
| Safety Valve Opening Pressure (Chamber) | 0.28 MPa |
| Safety Valve Opening Pressure (Jacket) | 0.28 MPa |
| Sterilization Temperature Control Accuracy | ±0.2 ℃ |
| Temperature Uniformity | ±1 ℃ |
| Number of Pulsations | Amplitude -80 to 80 kPa, Frequency 1 |
| Positive Pressure Fluctuation Cycles | 1 to 3 |
| Vacuum Pulsation (Amplitude & Frequency) | Amplitude -80 to 0 kPa, Frequency 1 to 99 |
| Ultimate Vacuum | -97 kPa |
| Vacuum Leakage Rate | ≤0.13 kPa/min |
| External Surface Temperature | ≤ Ambient + 20 ℃ |
| Steam consumption | 55 Kg/C |
| Vessel Design Life | 10 years (20,000 sterilization cycles) |
| Internal Tank Material | 304-08 |
| Jacket Material | Q245R |
| Jacket Design Pressure | 0.3 MPa |
| Built-in Steam Generator (if any) | 0.3 MPa |
| Inner Chamber Hydrostatic Test Pressure | 0.39 MPa |
| Jacket Test Pressure | 0.52 MPa |
| Temperature Display Accuracy | 0.1 ℃ |
| Pressure Display Accuracy | 0.1 kPa |
| Dryness After Sterilization | Fabric ≤0.6%, Utensils/Tools ≤0.1% |
| Single Phase Voltage Supply | 220 ±10% V, 50 Hz |
| Three Phase Voltage Supply | 380 ±10% V, 50 Hz |
| Pure Steam (Self-produced) | 0.25 to 0.35 MPa (None) |
| Industrial Steam (Self-produced) | 0.3 to 0.5 MPa (None) |
| Water Softening | 0.15 to 0.3 MPa |
| Purified Water/Water for Injection | 0.15 to 0.3 MPa (for self-produced steam) |
| Compressed Air | 0.4 to 0.7 MPa |
| Depth | 1815 |
| Motor Power | 3.5 kW |
| Heating Power | 48 kW |
| Power Supply | 380 V, 50 Hz |
| Dimensions (L×W×H) | 2100 × 1350 × 2000 mm |
| Weight | 1550 kg |
Horizontal Autoclave FM-HA-B103 is used for sterilizing laboratory instruments, clothing, rubber stoppers, filters, culture media, and other reusable materials. It is suitable for hospitals, pharmaceutical and biotechnology facilities, and research laboratories.
Fison horizontal autoclave range designed for high-capacity steam sterilization in laboratory environments, suitable for sterilizing culture media, glassware, instruments and heat-resistant materials. The series includes front-loading cylindrical and rectangular chamber designs made from corrosion-resistant stainless steel, supporting working temperatures up to 150°C and working pressure up to 0.25 MPa. This horizontal sterilizer features advanced models with digital control systems, thermo-pressure controllers, safety alarms, automatic water cut-off and buzzer alerts for controlled operation. Capacity options range from 90 L to 1000 L, covering multiple chamber sizes for varied sterilization requirements.