Spin Tissue Processor FM-STP-A100 is a 12-station carousel system designed for efficient tissue processing. It has a 2.3 L capacity and nine containers to ensure consistent, automated tissue infiltration. Our processor features a large LCD interface, customizable timing, and vacuum options for precise control. It provides reliable tissue dehydration and paraffin embedding, making it suitable for both clinical and research uses.
$7,762.00
Specifications
Reagent Container Capacity | 2.3L |
Wax Paraffin Container Capacity | 1.8L |
System Type | Carousel, 12 stations |
Reagent Container | 9 |
Wax Paraffin Container | 3 |
Wax Temperature Range | 60°C to 99°C |
Tissue Basket Stirring Interval | 1 min every 5 min |
Display | LCD(160×90 mm) Foil protected keyboard |
Delayed Start Time | Up to 30 days |
Programmable Infiltration Time | 30 days |
Number of Programs | 10 selectable, editable |
Vacuum Pressure Capacity | Max 0.05 Mpa (~0.5 bar) |
Tissue Basket Size | Φ130×110 mm |
Standard Basket Capacity | Max 90 cassettes 1 basket (optional 2) |
Power Consumption | 400 to 500 W |
Power Supply | AC220V/110V, 50 Hz |
Dimensions | 780×570×690 mm |
Package Dimensions(machine) | 880× 880× 800 mm |
Package Dimensions(tanks) | 620× 410× 530 mm |
Net Weight | 70kg |
Gross Weight | 110kg |
Features
Applications
Accessories
Accessory | Quantity |
Reagent Bottle | 9 pcs |
Paraffin Wax Tank | 3 pcs |
Paraffin Wax Tank Connection Line | 3 pcs |
Tissue Basket | 1 pcs |
Tissue Cassette | 20 pc |
Hexagonal Wrench | 1 pc |
Screwdriver | 1 pc |
Fuse (5A) | 1 pcs |
Power Line | 1 line |
Frequently Asked Question
1: What type of control system does the Spin Tissue Processor FM-STP-A100 use?
Spin Tissue Processor FM-STP-A100 uses a PLC, offering industrial-grade reliability and high-precision control over every processing step.
2: Can I delay the start of a tissue processing cycle in Spin Tissue Processor FM-STP-A100?
Yes, Spin Tissue Processor FM-STP-A100 allows you to schedule a delayed start up to 30 days, making it ideal for automated overnight or weekend runs.
3: In Spin Tissue Processor FM-STP-A100, how does vacuum agitation improve tissue processing?
In Spin Tissue Processor FM-STP-A100 Vacuum, agitation enhances reagent penetration, improving dehydration uniformity and minimizing processing artefacts in dense or fatty tissues.
4: In the Spin Tissue Processor FM-STP-A100, can I program different times for each station?
Yes, Spin Tissue Processor FM-STP-A100, every station is independently programmable with up to 999 minutes per step, giving you full control over infiltration time.
5: Can I change a program during an active run in Spin Tissue Processor FM-STP-A100?
Yes, Spin Tissue Processor FM-STP-A100 system allows real-time editing of the processing program without interrupting the cycle, saving time and increasing flexibility.
Fison’s Spin Tissue Processors are high-precision, automated carousel-type systems designed to streamline the tissue preparation workflow in biomedical research laboratories. Engineered with high-quality processing stations and maximum reagent capacity, it delivers reliable tissue dehydration, clearing, and paraffin infiltration with minimal operator intervention. Our Spin Tissue Processors feature programmable logic control (PLC), vacuum agitation for enhanced reagent penetration, and an anti-collision basket system to ensure sample safety. Whether deployed in clinical pathology, academic institutions, or pharmaceutical R&D, the Spin Tissue Processors ensure efficient, reproducible tissue processing, supporting the creation of high-quality paraffin-embedded specimens for microscopic examination.